Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera

Product Details
Customization: Available
Classification: Ophthalmic Instruments
Type: Fundus Camera

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Experienced Team
The supplier has 18 foreign trading staff(s) and 12 staff(s) with over 6 years of overseas trading experience
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (16)
  • Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
  • Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
  • Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
  • Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
  • Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
  • Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
Find Similar Products

Basic Info.

Model NO.
Kestrel 300
Certification
CE
Group
All
Acquisition Modes
Non-Mydriatic/ Mydriatic
Field of View
50°
Working Distance
15mm
Minimum Pupil Size
≥3.0mm
Focus Modes
Auto /Manual
Exposure Modes
Auto /Manual
Operation
Auto /Manual
Photography
CMOS
Resolution
20megapixels
Diopter Compensation
±15D
Fixation
Internal Fixation
Autofocus Assistance
Dual Camera
Dicom 3.0
Yes
Customization Ai Port
Yes
Dimensions
284mm( L)X306mm(W)X145mm(H)
Transport Package
Standard Exporting Packaging
Specification
Small
Trademark
Visionstar
Origin
Chongqing, China
Production Capacity
1000 Units/Month

Product Description

Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera

Kestrel 300 Portable A.I. Robotic Fundus Camera

 

Kestrel300 is a brand new, fully automatic, portable fundus camera with compact design, easy-to-carry features, fully automated design, and user-friendly operation. It comes equipped with a high-definition image acquisition system that allows for easy uploading of images to the cloud. With the help of AI technology, it enables artificial intelligence film reading and allows you to have access to an eye health expert anytime and anywhere.

 

Features:

Portable
Apply to any medical and health scene
Compact appearance, net weight only 3.5Kg, highly portable;
The Kestrel300 is applicable for large-scale population screening in hospitals, optometry centers, physical examination institutions, as well as other large health fields and scenes, such as insurance companies and pharmacies.

Fast
Complete a binocular examination in 30 seconds and provide immediate results.
The Kestrel300 features a fully automatic operation process allowing the examinee to complete a fundus examination of both eyes in just 30 seconds without requiring mydriasis. This greatly improves the efficiency of diagnosis and treatment.

Intelligent
Self-service operation, artificial intelligence film reading
Built-in voice system guides users through the detection process for a self-guided experience.
Results can be uploaded to cloud servers for AI-based image analysis.
The Kestre1300 can help reduce the demand for healthcare professionals to perform fundus examinations and image analysis, thus addressing the shortage of ophthalmologists in primary healthcare institutions.
High definition
High-definition images with 20 million pixels.
Clear fundus imaging is crucial for the accurate diagnosis of retinal diseases.
The Kestrel 300 features a built-in 20 million high-definition pixel CCD
designed specifically for fundus imaging, along with an automatic focusing and exposure system that allows for perfect presentation of fundus details.

 

 

Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera

 

High Definition Fundus Images

 

Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera


Specifications

 

Image acquisition system  
Acquisition modes Non-mydriatic/ mydriatic
Field of view 50°
Working distance 15mm
Minimum pupil size ≥3.0mm
Focus modes Auto /manual
Exposure modes Auto /manual
Operation Auto /manual
Photography CMOS
Resolution 20megapixels
Diopter compensation ±15D
Fixation Internal fixation
Autofocus assistance Dual Camera
DICOM 3.0 Yes
Customization AI port Yes
Others  
Dimensions 284mm( L)x306mm(W)x145mm(H)
Weight 3.6kg
Power supply 100-240V 50/60Hz

Services
Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
Packaging
Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera
Kestrel 300 Portable a. I. Robotic Eye Fundus Camera Non-Mydriatic/Mydriatic Retinal Camera

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More