Customization: | Available |
---|---|
Classification: | Radiology Equipment |
Type: | C-Arm X-ray Machine |
Still deciding? Get samples of US$ 26000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Pelvis | Cervical Vertebra side |
Hand | Knee Joint side |
Monoblock | |
Focus | 0.6/1.8 or(0.3/1.5) |
Anode Capacity | 35.5kJ(47kHu) |
Tube Heat Capacity | 650kJ(867kHu) |
Power Output | 5kW |
Inverter Frequency | ≥40kHz |
Continous Fluoroscopy (Manual/ Automatic) |
Tube voltage: 40kV~120kV Tube current: 0.3mA~4mA Automatic brightness tracking function |
Pulse Fluoroscopy |
Tube voltage: 40kV~120kV; Tube current: 0.3mA~30mA Pulse frequency: intelligent control reduces the radiation dose, improves the quality of single frame image and improves the continuous working time |
Radiography Mode |
Radiography: 40kV~120kV Radiography tube current: 25mA~100mA Radiography mAs: 1.0mAs~180mAs |
Beam Limiter | Electric iris + linear symmetrical rotatable |
Working Environment Conditions |
Environment temperature: 10°C-40°C Relative humidity: 30%-75% Atmospheric pressure: 700hpa-1060hpa |
Operating Power Condition |
Power supply voltage and phase number: single-phase 220V ± 22V Power frequency: 50Hz±1Hz Internal resistance of power supply: no more than 1 Ω |
Imaging System | |
Image Intensifier | 9″ three field e5764sd-p3, center resolution 4.8lp/mm |
Camera | Ultra-low illumination, one million pixel black and white progressive scanning |
LCD | 24 inch ordinary LCD, resolution 1920×1200, working frequency: 60Hz |
Image Acquisition and Processing Workstation |
Registration: Registration preservation, medical record query, worklist Acquisition: start acquisition, prepare recording, reset, horizontal mirror, vertical mirror, window adjustment, magnifying glass, negative image, edge enhancement, recursive noise reduction Processing: four windows, nine windows, sharpening, horizontal mirror, vertical mirror, text annotation, length measurement Report: save, preview, expert template DICOM function: DICOM browsing, network service |
Image Definition Index | Gray level: ≥ 11; Line pair resolution: ≥ 2.0lp/mm |
Mechanical part | |
Forward and Backward Movement | 200mm |
Rotation Around Horizontal Axis | ± 180 ° |
Rotation Around Vertical Axis | ± 15 ° |
Focal Screen Distance | 1000mm |
C-arm Opening | 770mm |
Arc Depth of C Arm | 680mm |
Sliding along the Track | 120 ° (+ 90 ° ~ - 30 °) |
Electric Lifting of Column | 400mm |
Guide Wheel and Main Wheel | the guide wheel can rotate in any direction, and the main wheel can rotate ± 90 ° |
With electric auxiliary support arm | |
Full balance: when the mechanical movement of the equipment is unlocked, the C-arm is balanced at any position and angle without sliding | |
Light thrust |
Configuration | |
1 | New (with electric auxiliary support arm) C-arm Frame |
2 | High-frequency high-voltage X-ray generator and high-frequency inverter power supply |
3 | 24 inch ordinary LCD, resolution 1920×1200 |
4 | 19 inch ordinary LCD, resolution 1280 * 1024 |
5 | 9 Inch three field image intensifier |
6 | Megapixel ultra-low illumination digital camera, Camera pixel matrix description: 1024×1024 |
7 | Digital acquisition and processing workstation |
8 | Dense grid |
9 | Electric adjustable beam collimator |
10 | handheld controller |
11 | Laser cross positioner |
12 | Digital work station |