XCR5K C-arm X-ray System
Features:
1. High -frequency generator emits high-quality and hard x-rays with strong penetrability
2. 21cm*21cm flat panel detector, which has bigger image size than image intensifier
3. Amorphous silicon flat panel makes the surgery more accurate for the clinical operation due to high density resolution and spatial resolution
4. High stability oil-cooled heat-resistant combined tube, support long-time image acquisition in surgery, satisfy the requirement of long-time operation
5. Microcomputer control system with self-diagnostic function and automatic protection
6. Double CPU control improves the stability and safety of the equipment
7. Large opening design provides larger free diagnosis spaces, and maximizes the efficiency of surgery environment
8. Hand switch, foot switch and remote control make sure that you could do exposure inside and outside the operating theatre
9. PACS connectivity with DICOM 3.0 is convenient to send, receive and print images
Technical Data
Model |
XCR5K |
XCR15K |
X-ray Generator |
Output power |
5KW |
15KW |
Current of fluoroscopy |
0.3-6.3mA |
Current of radiography |
0.5-150mA |
0.1-100mA |
Pulsed mA |
32mA |
Voltage |
40kV-125kV |
mAs range |
0.2-100mAs |
ms range |
10-1600ms |
X-ray Tube |
Anode type |
Rotating Anode |
Focal Spot value |
0.3mm /0.6mm |
Rotating anode speed |
2800rmp |
Anode heat storage |
300KHU |
Housing Heat Storage Capacity |
1200KHU |
Flat-panel Detector |
Size |
21*21cm |
Detector Technology |
Amorphous Silicon |
Scintillator |
CsI |
Image resolution |
2.5lp/mm |
Frame rate |
MAX 30frames/sec |
Active pixels |
1024*1024 pixels |
A/D conversion |
16 bit |
Pixel Pitch |
205 μm |
Faster image capture speed |
The image will be displayed on the monitors in 0.8S after exposure |
Grid |
Ratios |
10:01 |
Density |
60l/cm |
SID |
100cm |
C-arm Unit |
SID |
1000mm |
Free space(Tube to I.I) |
820mm |
Arc depth |
640mm |
Vertical movement |
0-400mm(Electric) |
Horizontal movement |
0-200mm(Manual) |
Planning movement |
±15°(Manual) |
Orbital movement |
-30°-+90°(Manual) |
C-arc rotation |
±180° |
Workstation & Software |
Monitor |
One set 34'' LCD HD monitor |
Computer memory |
500G mass storage |
CPU |
2.7GHZ |
Software |
The image can be step-less rotated continuously for 360° |
Flip the Reference image horizontally or vertically |
Applies various Gamma values for each image |
Last frame frozen |
Images can be saved in different formats, such as JPG, DCM, RAW, etc |
DICOM 3.0. Data communication. Data storage |
Standard configuration |
High-voltage Generator |
5KW |
15KW |
Rotating X-ray Tube |
1 set |
Grid |
1 set |
21*21cm Flat Panel Detector |
1 set |
Mechanical Frame |
2 sets |
Laser Positioning Device |
1 set |
Image Capturing and Processing Software |
1 set |
Computer |
1 set |
34″ Medical LCD Monitor |
2 sets |
Exposure Switch |
1 set |