Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer

Chongqing Vision Star Optical Co., Ltd.
  • Audited Supplier
  • 12 yrs

Contact Supplier

Product Highlights

  • Automatic Measurement: Features auto chinrest adjustment, auto alignment, auto focus, and auto left/right eye switching.
  • Corneal Thickness Measurement: NCT-200A model supports corneal thickness measurement (400-800um) for pressure compensation and calibration.
  • 24-Hour Dynamic Monitoring: Capable of monitoring intraocular pressure dynamically for 24 hours and printing data on the same report.
  • DICOM 3.0 Networking: Connects to hospital database systems for data archiving and reading, conforming to modern hospital standards.
  • Safety Limit System: Prevents nozzle contact with eyes; triggers an alarm buzzer if the air jet mouth is too close.
  • Multiple Measurement Modes: Supports fully automatic, automatic, and manual focusing modes with 3D full auto focus capability.
  • CE and FDA Certified: Product holds CE and FDA certifications ensuring compliance with international safety and quality standards.

Product Images of Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer

Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer pictures & photos
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer pictures & photos
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer pictures & photos
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer pictures & photos
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer pictures & photos
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer pictures & photos
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
  • Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
  • Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
    Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
  • Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
    Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
  • Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
    Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
  • Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
    Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
  • Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
    Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
  • Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
    Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer

Find Similar Products

Product Description

Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Nct-200  Ophthalmic Full Automatic Detection Non-contact Tonometer

Features:
*Auto chinrest adjustment.
*Fast, safe and convenient.
*Rotatable 7 inches color LCD touch screen.
*Without cornea thickness. (NCT-200)
*With cornea thickness. (NCT-200A)
*Touch lightly, 3D automatic intraocular pressure measurement for both eyes. Auto soft air puff, auto alignment and auto focus, auto left and right eye switch.
*Air jet test: after the machine is turned on, check whether the measuring system of the instrument works normally.
*Safety limit: It can avoid the contact between the air jet mouth and the patient's eyes. When the alir jet mouth is too close to the patient's eyes, the buzzer will give an alarm.
*It can monitor intraocular pressure dynamically 24 hours, and print it on the same report sheet with intraocular pressure data.
*The touch control screen can be turned 180° up and down, 60° left and right, which is convenient for the operator to support the patient and lift the eyelid.
*The accurate corneal thickness measurement function is provided to provide intraocular pressure compensation value and automatically calibrate the intraocular pressure value.
*The machine can be connected to the database system through DICOM3.0 to archive and read the data, which conforms to the new era hospital standard

Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Specifications:

Display 7" 1024 * 600 color touch screen. Support up and down 180°, left and right 60° turning
Corneal thickness measurement Support (NCT-200A)
Measurement range CT 400-800um
Measurement increment-CCT 10um
Light Source Blue LED
Fixation lamp 1 internal fixation lamp (green LED), 2 external fixation lamps
Measuring head moving range Up and down stroke: 45 mm, Left and right stroke: 90 mm. Front and back stroke: 40 mm
Lifting range of lower jaw drag 68 mm
Working distance 11 mm (calculated from the front of nozzle)
Measurement accuracy 1mmHg (0.133Kpa )
Measuring range 0-60mmhg (0-8kpa) (including free switching between 30 / 60mmhg)
Power Supply AC100-240V, 50/60HZ
Ambient temperature 50°
Scope of operation 16mmx10mm
Printer Built in thermal printer, automatic paper cutting
Data storage Internal memory card + optional external USB memory
Networking DICOM3.0
Measurement mode Fully automatic / automatic / manual
Operating system Embedded system
Mobile platform Fully automatic platform / manual platform
Data input and output
Input: USB
Output: LAN/ RS232C
Focusing mode 3D full auto focus / manual focus
Jet detection
After power on, check whether the measuring system of the instrument works normally
Safety limit Support
Intraocular pressure
measurement
Each eye was measured three times continuously, and the average value was
calculated
Normal intraocular pressure range: 10-21mmhg (1.33kpa-2.80kpa)
Corneal thickness measurement
Each eye was measured three times continuously, and the average value was
calculated
Normal corneal thickness: about 550um
Full automatic measurement
Press the measurement button to complete the intraocular pressure test
automatically
24-hour dynamic intraocular
pressure measurement
It can monitor intraocular pressure measurement dynamically 24 hours, and print it
on the same report sheet with intraocular pressure data
Printing Data can be printed directly after measurement
Storage 10 sets of measurement data can be stored
Data export Can be exported to PDF or JPG format
Size and weight 500*300*500, <25kg
 
Services
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Packaging
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer

Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249471". Items marked "verified" are certified.

Watch Video
Watch Video
Chongqing Vision Star Optical Co., Ltd.
Chongqing Vision Star Optical Co., Ltd.
Chongqing Vision Star Optical Co., Ltd.
Chongqing Vision Star Optical Co., Ltd.
Chongqing Vision Star Optical Co., Ltd.
Chongqing Vision Star Optical Co., Ltd.
Chongqing Vision Star Optical Co., Ltd.
Chongqing Vision Star Optical Co., Ltd.

About Our Factory & Business Background

Address
2015, 4th Building, Longhu Jinshatianjie, Shapingba, 400030, Chongqing, China
Terms of Payment
T/T, Western Union, Money Gram, Credit Card
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, CIP
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
shenzhen, shanghai, guangzhou

Our Production Capability & Technical Expertise

Main Products
Auto Refractometer, Lensmeter, Slit Lamp, Lens Edger, Ophthalmic, Phoropter, Fundus Camera, Optical Lens, Tonometer, Ultrasound

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Western Europe

FAQ

What is the warranty period for this machine?
The machine comes with a 1-year warranty.
Does this tonometer support corneal thickness measurement?
Yes, the NCT-200A model supports corneal thickness measurement with a range of 400-800um and an increment of 10um.
What is the measuring range for intraocular pressure?
The measuring range is 0-60mmHg (0-8kPa), including free switching between 30/60mmHg.
Can the machine be customized?
No, this product is non-customized.
What are the dimensions and weight of the device?
The size is 500*300*500mm and the weight is less than 25kg.
How many sets of data can be stored?
The device can store up to 10 sets of measurement data using internal memory or optional external USB.
What is the average lead time for delivery?
The lead time is within 15 workdays for both peak and off-peak seasons.
Does the machine support data export?
Yes, data can be exported to PDF or JPG format.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now