Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Contact Supplier
Product Highlights
- Automatic Measurement: Features auto chinrest adjustment, auto alignment, auto focus, and auto left/right eye switching.
- Corneal Thickness Measurement: NCT-200A model supports corneal thickness measurement (400-800um) for pressure compensation and calibration.
- 24-Hour Dynamic Monitoring: Capable of monitoring intraocular pressure dynamically for 24 hours and printing data on the same report.
- DICOM 3.0 Networking: Connects to hospital database systems for data archiving and reading, conforming to modern hospital standards.
- Safety Limit System: Prevents nozzle contact with eyes; triggers an alarm buzzer if the air jet mouth is too close.
- Multiple Measurement Modes: Supports fully automatic, automatic, and manual focusing modes with 3D full auto focus capability.
- CE and FDA Certified: Product holds CE and FDA certifications ensuring compliance with international safety and quality standards.
Product Attributes
- Customization
- Available
- Customized
- Non-Customized
- Certification
- CE, FDA
- Model NO.
- NCT-200
- Scale
- Medium
- Model
- Nct-200 Non Contact Tonometer
- Located
- Chongqing
- Application
- Hospitals, Eye Clinics
- Warranty
- 1 Year
- Product Name
- Non Contact Tonometer
- Display
- 7" 1024 * 600 Color Touch Screen Support up and Do
- Corneal Thickness Measurement
- Support (Nct-200A)
- Measurement Range CT
- 400-800um
- Measurement Increment-CCT
- 10um
- Light Source
- Blue LED
- Fixation Lamp
- 1 Internal Fixation Lamp (Green LED), 2 External F
- Lifting Range of Lower Jaw Drag
- 68 mm
- Working Distance
- 11 mm (Calculated From The Front of Nozzle)
- Measurement Accuracy
- 1mmhg (0.133kpa )
- Measuring Range
- 0-60mmhg (0-8kpa) (Including Free Switching Betwee
- Transport Package
- Standard Exporting Package
- Trademark
- VSO
- Origin
- Chongqing, China
- Production Capacity
- 100 Units/Month
Product Images of Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Find Similar Products
Product Description

Nct-200 Ophthalmic Full Automatic Detection Non-contact Tonometer


Specifications:
| Display | 7" 1024 * 600 color touch screen. Support up and down 180°, left and right 60° turning |
| Corneal thickness measurement | Support (NCT-200A) |
| Measurement range CT | 400-800um |
| Measurement increment-CCT | 10um |
| Light Source | Blue LED |
| Fixation lamp | 1 internal fixation lamp (green LED), 2 external fixation lamps |
| Measuring head moving range | Up and down stroke: 45 mm, Left and right stroke: 90 mm. Front and back stroke: 40 mm |
| Lifting range of lower jaw drag | 68 mm |
| Working distance | 11 mm (calculated from the front of nozzle) |
| Measurement accuracy | 1mmHg (0.133Kpa ) |
| Measuring range | 0-60mmhg (0-8kpa) (including free switching between 30 / 60mmhg) |
| Power Supply | AC100-240V, 50/60HZ |
| Ambient temperature | 50° |
| Scope of operation | 16mmx10mm |
| Printer | Built in thermal printer, automatic paper cutting |
| Data storage | Internal memory card + optional external USB memory |
| Networking | DICOM3.0 |
| Measurement mode | Fully automatic / automatic / manual |
| Operating system | Embedded system |
| Mobile platform | Fully automatic platform / manual platform |
| Data input and output |
Input: USB
Output: LAN/ RS232C
|
| Focusing mode | 3D full auto focus / manual focus |
| Jet detection |
After power on, check whether the measuring system of the instrument works normally
|
| Safety limit | Support |
|
Intraocular pressure
measurement
|
Each eye was measured three times continuously, and the average value was
calculated
Normal intraocular pressure range: 10-21mmhg (1.33kpa-2.80kpa)
|
| Corneal thickness measurement |
Each eye was measured three times continuously, and the average value was
calculated
Normal corneal thickness: about 550um
|
| Full automatic measurement |
Press the measurement button to complete the intraocular pressure test
automatically
|
|
24-hour dynamic intraocular
pressure measurement
|
It can monitor intraocular pressure measurement dynamically 24 hours, and print it
on the same report sheet with intraocular pressure data
|
| Printing | Data can be printed directly after measurement |
| Storage | 10 sets of measurement data can be stored |
| Data export | Can be exported to PDF or JPG format |
| Size and weight | 500*300*500, <25kg |
Packaging
About the Supplier
This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR249471". Items marked "" are certified.
Company Profile
Chongqing Vision Star Optical Co., Ltd (hyvisionstar. En. Made-in-China. com) is a professional ophthalmic equipment and optical instruments manufacturer in China. Since 1999, we have been manufacturing and selling Slit Lamp, tonometer, Retina Camera, Fundus camera & FFA, Ultrasound (A scan, AB scan, Pachymeter, Biometer & Pachymeter), Auto Perimeter (Vision Field Analyzer, Projection Perimeter), Phasco Emulsifier, Corneal Topography, Ophthalmoloscope, Retinoscope, Operation Microscope, Visual Electro System, OCT, Auto refractometer, Auto Ker-Refractometer, Auto Lensmeter, Auto Phoropter (view tester), Chart Monitor, Near Vision Tester, Combined unit (combined stand and chair), Keratometer, Trail Frame, Trail Lens Set, Auto Edger and so on.
Our factory is always concentrated on improving manufacturing technology and product quality, and our products have got CE certificate and some of them have FDA. Our factory covers about 20, 000, incdluing modern high-tech manufacturing workshop, independent research and development center, comprehensive laboratory and sales department. Our product have been sold to more than 60 countries in the world. Our optical and ophthalmic instruments have been highly praised by thousands hospitals and optic glasses stores.
We provide our customers not only the best products but also the greatest services. We offer 1-3 years quality warranty and competitive price, free online training and technical support and satisfactory after services for all products. Our aim is to try our best to serve optics and ophthalmology.
We hope to establish mutual cooperation with customers all over the world.
Chongqing Vision Star Optical Co., Ltd
https://hyvisionstar.en.made-in-china.com/
About Our Factory & Business Background
- Address
- 2015, 4th Building, Longhu Jinshatianjie, Shapingba, 400030, Chongqing, China
- Terms of Payment
- T/T, Western Union, Money Gram, Credit Card
- International Commercial Terms(Incoterms)
- FOB, EXW, CFR, CIF, CIP
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- shenzhen, shanghai, guangzhou
Our Production Capability & Technical Expertise
- Main Products
- Auto Refractometer, Lensmeter, Slit Lamp, Lens Edger, Ophthalmic, Phoropter, Fundus Camera, Optical Lens, Tonometer, Ultrasound
Our Industry Experience & Global Business Record
- Export Year
- 2005-06-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Western Europe
FAQ
- What is the warranty period for this machine?
- The machine comes with a 1-year warranty.
- Does this tonometer support corneal thickness measurement?
- Yes, the NCT-200A model supports corneal thickness measurement with a range of 400-800um and an increment of 10um.
- What is the measuring range for intraocular pressure?
- The measuring range is 0-60mmHg (0-8kPa), including free switching between 30/60mmHg.
- Can the machine be customized?
- No, this product is non-customized.
- What are the dimensions and weight of the device?
- The size is 500*300*500mm and the weight is less than 25kg.
- How many sets of data can be stored?
- The device can store up to 10 sets of measurement data using internal memory or optional external USB.
- What is the average lead time for delivery?
- The lead time is within 15 workdays for both peak and off-peak seasons.
- Does the machine support data export?
- Yes, data can be exported to PDF or JPG format.
Send your message to this supplier
People who viewed this also viewed
-
US$1,800.00-2,200.00 / Piece
-
US$230.00-300.00 / Piece
-
US$1,900.00-2,050.00 / Piece
-
US$7,000.00-7,890.00 / Piece
-
US$2,000.00-3,800.00 / Piece
-
US$1,350.00-1,800.00 / Piece
-
US$70.00-120.00 / Piece
-
US$100.00-200.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Ophthalmic Equipment
- Tonometer
- Noncontact Tonometer Full Automatic Iop Eye Pressure Machine Test Ophthalmology Non-Contact Tonometer
Related Categories
Hot Searches
- Home Machine
- Body Machine
- Portable Machine Factories
- Therapy Machine Factories
- Blood Pressure Machine
- Pressure Sterilizing Machine
- Pressure Steam Sterilizer Machine
- Pressure Slimming Machine
- Pressure Machine Massage
- Non-Contact Tonometer Bulkbuy