* The first intelligent XCT350 in China with 180° fixed angle and dual-head technologies
* Large, rectangular high-resolution digital detector
* Integrated with various collimators for various clinical applications
* Multi-functional examination table for different angles of examination
* Proprietary software system with English and Chinese language versions
* Comprehensive clinical process TCP and report system
* Standard DICOM interface for network & remote diagnosis
* Intelligent design for easy operation
* Excellent after-sales service, low running cost.
Specifications | ||
No. | Item | Specification |
1 | Detector | |
1.1 | Detector number | 2 pc, full digital, rectangle |
1.2 | Detector FOV | 360mm×500mm |
1.3 | Photomultiplier | 55×2 |
1.4 | Crystal | Sodium iodide, thickness: 9.5mm |
1.5 | Energy range | 50keV~400keV |
1.6 | Inherent energy resolution (99mTc) | ≤9.9% |
1.7 | Inherent space resolution | |
1.7.1 | Central FOV (FWHM) | ≤3.5mm |
1.7.2 | Central FOV (FWTM) | ≤6.5mm |
1.7.3 | Effective FOV (FWHM) | ≤3.5mm |
1.7.4 | Effective FOV (FWTM) | ≤6.5mm |
1.8 | Intrinsic uniformity | |
1.8.1 | Central FOV (differential) | ≤2.2% |
1.8.2 | Central FOV (integral) | ≤3.0% |
1.8.3 | Effective FOV (differential) | ≤2.5% |
1.8.4 | Effective FOV (integral) | ≤3.0% |
1.9 | Inherent lineation | |
1.9.1 | Differential lineation (Central FOV) | ≤0.7mm |
1.9.2 | Differential lineation(effective FOV) | ≤1.0mm |
1.9.3 | Absolute linearity (Central FOV) | ≤2.0mm |
1.9.4 | Absolute linearity (effective FOV) | ≤2.0mm |
1.1 | Maximum count rate (@ window | 130 kcps |
width 20%) | ||
1.11 | System resolution (low energy high | ≤8.0mm |
collimator) | ||
1.12 | System sensitivity (low energy high | ≥71cpm/μCi |
resolution collimator) | ||
1.13 | Planar sensitivity difference between | ≤5% |
detectors | ||
1.14 | System space resolution(low energy high resolution collimator, FWHM) | |
1.14.1 | Axial direction | 9.0mm |
1.14.2 | Agittal direction | 12.0mm |
1.14.3 | Tangential direction | 10.0mm |
1.15 | Detector movement | Rotation: 90 º Up-down: 200mm |
1.16 | Aver. Rotation center offset ≤2.5mm(low energy general collimator) | ≤3mm(low energy high resolution |
collimator) | ||
2 | Gantry | |
2.1 | Weight(without collimator) | ≤2300kg |
2.2 | Bore | ≥64cm |
2.3 | Rotation | |
2.3.1 | Rotation range | ≥225º |
From -45 º~180 º | ||
2.3.2 | Min. rotation speed | ≤0.040RPM |
2.3.3 | Rotation precision | ≤1º |
2.4 | Position monitor | 12" color screen |
2.5 | Patient safe belt | Yes |
2.6 | Gantry type | None cantilever type |
2.7 | Control box | 1 pc |
2.8 | Gantry accessories | |
2.8.1 | Supporting structure | 1 pc |
2.8.2 | Turn plate | 1 pc |
2.8.3 | Motion control system | 1 set |
2.8.4 | Power cabinet | 1 set |
3 | Patient table | |
3.1 | Table material Attenuation | ≤10% |
3.2 | Weight capacity | 0~135kg |
3.3 | Scan range | ≥190cm |
3.4 | Position precision | ≤2mm |
3.5 | Vertical movement range | 1140mm~650mm |
3.6 | Horizontal movement | |
3.6.1 | Max. speed | ≥30cm/min |
3.6.2 | Min. speed | ≤12cm/min |
3.7 | Vertical movement speed | 20mm/s |
3.8 | Head support | 1 pc |
3.9 | Table support | 1 set |
3.1 | Motor | 2 set |
4 | Collimator | |
4.1 | Low energy high resolution type collimator (Standard) | 2 pc |
4.1.1 | Low energy high resolution collimator weight | ≤35kg per unit |
4.2 | High energy general type collimator (optional) | 2 pc |
4.2.1 | High energy general type collimator weight | ≤75kg/unit |
4.3 | Low energy general type collimator (optional) | 2 pc |
4.3.1 | Low energy general type collimator weight | ≤50kg/unit |
4.4 | Collimator replacement device | 1 pc for each collimator |
5 | Acquisition workstation | |
5.1 | OS | Windows |
5.2 | CPU | ≥2.8GHz |
5.3 | RAM | ≥2GB |
5.4 | HDD | ≥320GB |
5.5 | Monitor | ≥19" |
5.6 | Recorder | CRW/DVD |
5.7 | Keyboard and mouse | 1 pc |
5.8 | DICOM3.0 | Yes |
6 | Post processing workstation | |
6.1 | OS | Windows |
6.2 | CPU | ≥2.8GHz |
6.3 | RAM | ≥2GB |
6.4 | HDD | ≥320GB |
6.5 | Monitor | ≥19" |
6.6 | Recorder | CRW/DVD |
6.7 | Keyboard and mouse | 1 pc |
6.8 | DICOM3.0 | Yes |
7 | Software function | |
7.1 | Language English | |
7.1.1 | Static collection | Yes |
7.1.2 | Whole body scan acquisition | Yes |
7.1.3 | Dynamic collection | Yes |
7.1.4 | Section | Yes |
7.2 | General image display and analysis | Yes |
7.2.1 | Zoom in, zoom out, copy | Yes |
7.2.2 | Image filter | Yes |
7.2.3 | Cine function | Yes |
7.2.4 | ROI establish, display and statistics | Yes |
7.2.5 | Palette function | Yes |
7.2.6 | Window width/level | Yes |
7.3 | Curve computing software | Yes |
7.3.1 | Time radioactive curve | Yes |
7.3.2 | Image mathematical function | Yes |
7.3.3 | Measurement function | Yes |
7.4 | Organ function analysis | |
7.4.1 | Bone imaging and analysis | Yes |
7.4.2 | Bone sectional imaging analysis | Yes |
7.4.3 | Full body imaging and analysis | Yes |
7.4.4 | Thyroid imaging and analysis | Yes |
7.4.5 | Thyroid sampling and quantitative analysis | Yes |
7.4.6 | General image display and processing function | Yes |
7.5 | Renal function analysis | |
7.5.1 | Basic analysis | Yes |
7.5.2 | Dynamic analysis | Yes |
7.5.3 | Static analysis | Yes |
7.5.4 | GFR glomerular filtration rate analysis | Yes |
7.5.5 | Renal perfusion analysis | Yes |
7.5.6 | Left/right renal clearance rate analysis | Yes |
7.6 | Reconstruction | |
7.6.1 | Transversal reconstruction | Yes |
7.6.2 | Sagittal reconstruction | Yes |
7.6.3 | Coronal reconstruction | Yes |
7.6.4 | Customized cardiac sectional reconstruction | Yes |
7.7 | Report system English | |
7.7.1 | User information management system | Yes |
7.7.2 | Image printing software | Yes |
7.8 | Quality control software English | |
7.8.1 | Pixel size adjustment function | Yes |
7.8.2 | Automatic gain correction function | Yes |
7.8.3 | Energy correction function | Yes |
7.8.4 | Linearity correction function | Yes |
7.8.5 | Uniformity correction function | Yes |
8 | Quality control | |
8.1 | QC phantom | Yes |
8.2 | Source | Yes |
8.3 | User manual | Yes |
8.4 | Free software upgrading | Yes |