This X-ray system is specialized in veterinary digital radiography. It is suitable for any parts of pet. As its high-quality images and low-dose radiation, it is widely used in pet hospital.
VXR5KWA Portable Digital X-ray System |
VXR8KC Mobile Digital Radiography System |
VXR5CK Mobile Digital C-arm X-ray Machine |
VXR32A Floor-mounted Digital Radiography System |
Details for VXR5KWA Portable Digital X-ray System
Specification:
Model | VXR5KWA | VXR8KWB | VXR125C |
Power Output | 5kW | 8kW | 12.5KW |
Current | 10-100mA | 10-125mA | 10-160mA |
Voltage | 40-125kV | 40-125KV | 40-130KV |
mAs | 0.1-200mAs | 0.1-400mAs | 0.1-630mAs |
Exposure time | 1-4000ms | 1-6300ms | 1-6300ms |
Focus Size | 1.0/2.0 | 0.6/1.2 | 0.6/1.2 |
Specification of VXR5KWA:
Common Parameter | |
Output Power | 5.3kW |
Rated voltage | 220VAC, ±10%, 50Hz |
Inverter frequency | 100kHz ±5% |
kV accuracy | Full range: ±4% |
mA accuracy |
≤±(5% ) (mA>25mA, ms>5) ≤±(10% +1mA) (mA≤25mA) |
Anode speed | Fixed anode |
Exposure Parameter | |
Exposure KV range | 40kV-125kV, 1kV step |
Exposure mA range | 10-100mA(Adopt R'10 or R'20 standard) |
Exposure ms range | 1-4000ms (Adopt R'10 or R'20 standard) |
Exposure ms accuracy | ≤±(5% +0.2ms) |
Exposure mAs range | 0.1-200mAs (Adopt R'10 or R'20 standard) |
Exposure mAs accuracy | ≤±(5%+0.2mAs) |
Optional Parameter | |
Optional exposure technology |
kV-mAs kV-mA-ms |
APR | Supports up to 2000 APR data |
Communication Interface | RS-232, Supports communication with PC |
Dimensions(mm) | 280*255*220(Not include collimator) 450*255*220(Include collimator) |
Weight(kg) | 17kg(Include collimator and battery) |
Tube focus | Small focus 0.6, large focus 1.8 |
Battery Parameter | |
Battery capacity | 6Ah |
Rated voltage/current | 22.2V/1.2A |
Exposure interval | 1.5min |
Usage environment | Lithium battery charging temperature range: 0~40 degrees Celsius, lithium battery discharge temperature range -20~60 degrees Celsius. |
Storage environment |
* Lithium-ion batteries should be stored in a relatively cool, dry, and ventilated environment, away from fire sources and high temperatures. The battery storage temperature must be within the range of 0°C~45°C, and the humidity must be 65±20%RH. * Storage voltage and power: voltage is 22.2V~24.0V. * Long-term storage batteries(more than 3 months) must be placed in an environment with a temperature of 0-20°C and a humidity of 65±20% RH. |
Offline impressions | Fully charged, one exposure is 200. You can expose during the charging process. This is not recommended. |