XMM9800B Mammography System (Domestic X Ray Tube)
Feature:
1. X ray mammogram system with AEC function
2. The digital mammogram x ray machine is integrating designed, with beautiful appearance, manual operation,convenient operation and use, use the most popular keyboard, optical mouse operation.
3. Function of mammography machine:
Detect galactocele accurately
Detect intraductal papilloma
Detect mammary duct ectasia and acute mastitis
Detect proliferation of mammary gland and breast cancer
4. Comfortable compression of mammography machine: When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure (up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
Model |
Joint Venture Tube |
IAE tube |
VARIAN tube |
X-ray Generator |
|
Inverter frequency |
80 kHz |
Input Power |
220V AC, 50/60Hz(can change to 110V) |
Power Rating |
6 kW |
Focal |
Large Focal Point 20-35kV/10-510mAs; |
Small Focal Point 20-35kV/10-100mAs |
X-ray Tube |
Model |
China Hangzhou LR01 Tube |
IAE C339V |
VARIAN M113SP |
Focal Spot |
Dual Focus 0.2 / 0.4 mm |
Dual Focus 0.1 / 0.3 mm |
Target Material |
Molybdenum (Mo) |
Port Material |
Beryllium (Be) |
High-speed anode drive |
2800/1000 rpm |
Target angle |
12°/12° |
10°/16° |
AnodeHeat Storage |
100KJ (150KHU) |
210kJ (300kHU) |
Anode Cooling |
Air cooling |
Filtration |
Mo (0.03 mm), Al (0.5 mm) |
Radiographic Stand |
C-ARM |
Vertical Movement: 590mm |
|
Center of electric rotating C-arm, automatic return function by one key |
Rotations Degree |
-90° ~ +90° |
Automatically released after the exposure pressure settings display |
Compression flexible stepless speed |
Max. pressure |
200N |
Max. travel |
150 mm |
|
SID |
650 mm |
|
Cassette Image Receptor |
* 18 × 24 cm (24 cm X 30 cm optional) |
* 18×24 cm |
* 18×24 cm (24 cm X 30 cm optional) |
* Bucky Device: 18 × 24 cm Bucky drive mechanism, (24 cm X 30 cm, optional) |
* Bucky Device: 18×24 cm Bucky drive mechanism |
* Bucky Device: 18×24 cm Bucky drive mechanism (24 cm X 30 cm, optional) |
* Grid Ratio: 5:1, 30 Line/cm |
* Grid Ratio: 5:1, 30 Line/cm |
* Grid Ratio: 5:1, 30 Line/cm |
Weight |
300 kg (1.68 m3) |
Radiographic Stand |
C-ARM: Vertical Movement: 580 mm; Rotations Degree:+175° ~ -180°; SID: 650 mm |
Anode |
Rotated |
No. |
Configuration |
Quantity |
1 |
X-ray Tube |
1 |
2 |
X-ray Generator |
1 |
3 |
Radiographic Stand |
1 |
4 |
C-ARM |
1 |
5 |
Cassette Image Receptor |
1 |
6 |
compression devices |
1 |
7 |
Comfortable Compression |
1 |
8 |
paddle switch |
2 |
9 |
control console |
1 |
10 |
Exposal switch and connected line |
1 |
11 |
power wire |
1 |
12 |
grounded wire |
1 |
13 |
fuse |
2 |
14 |
operation manual |
1 |
15 |
Maintenance Reference Manual |
1 |