Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Still deciding? Get samples of US$ 43000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | XCA7000B | XCA7000C |
Electrical Performance | ||
High Frequency Inverter Power | Output power: 12.0kW | Output power: 16.0kW |
Inverter frequency: 60kHz | Inverter frequency: 60kHz | |
Continuous Fluoroscopy (Automatic, Manual) | Tube voltage: 40kV~125kV Tube current: 0.3mA~4mA | |
Intensifying Fluoroscopy (Automatic, Manual) | Tube voltage: 40kV~125kV Tube current: 0.3mA~8mA | |
Pulse Fluoroscopy (Automatic, Manual) | Tube voltage: 40kV~125kV Tube current: 0.3mA~30mA Pulse frequency: 1-10 frame/s |
|
DSI Digital Spot Film | 1-10 frame/s can be chosen | |
Radiography Tube Voltage | 40kV~125kV 160mA | 40kV~125kV 200mA |
X-ray Tube | ||
X-ray Tube Special For High Frequency | Rotary anode focus: 0.3/0.6 mm | |
Anode thermal capacity: 212kj (300KHU) | ||
Image System | ||
Image Intensifier | TOSHIBA 9″ Image intensifier | |
CCD Camera | Medical Mega-pixels digital CCD camera | |
CCU | Real time collection, horizontal, vertical mirror image, recursive noise reduction can be adjusted continuously, multi-images storage, image patching, last image freeze | |
Monitor | 19″ 1M medical LCD monitor | |
Work Station Software | Storage without damage, multi-images display, image W/L real time adjustment, grayscale switch, region of interest balance, GAMMA correction, flip, noise reduction, intensifying, smoothing, sharpening, compression, zoom in, measurement, remark, picture-text typeset print, expert template, DICOM image transmit, DICOM image print, cine loop, image imprinting, Work list registration, etc. | |
Structure Performance | ||
Direction Wheel, Main Wheel | Direction wheel 360°rotation, main wheel ±90°rotation | |
C-arm | Motorized forward and backward movement: 200mm | |
Motorized rotation around horizontal axis: ±180° | ||
Motorized slip on orbit: 120°(+90°~-30°) | ||
Motorized ascending and descending of pillar: 400mm | ||
Rotation around vertical axis: ±15° | ||
SID: 1060 mm open: 860 mm arc depth: 700 mm |
Configuration | ||
1 | Main frame of C-arm (Four-dimensional electric) | 1 |
2 | X-ray generator and high frequency inverted power supply | 1 |
3 | Toshiba 9'' image intensifier | 1 |
4 | Medical Mega-pixels digital CCD camera | 1 |
5 | CCU | 1 |
6 | Digital Acquisition and Processing workstation | 1 |
7 | 19'' 1M medical LCD monitor | 2 |
8 | Imported minigroove grid | 1 |
9 | Electric adjustable collimator | 1 |
10 | Human graphical LCD touch screen | 2 |
11 | Hand parameter controller | 1 |
12 | Hand Mechanical movement controller | 2 |
13 | Foot brake for exposure | 2 |
14 | Red light cross localization | 1 |
15 | Film hanger | 1 |