Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | MRI Scanner |
Still deciding? Get samples of US$ 400000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
No. | Item | Specification |
1 | Magnet System | |
1.1 | Magnet Type | Permanent magnet with automatic constant temperature system |
1.2 | Field strength | 0.22T |
1.3 | Magnet shape | H shape |
1.4 | Homogeneity (16cm,DSV,VRMS) | ≤4.5ppm |
1.5 | Shim method | Active/Passive/Dynamic |
1.6 | Magnet gap | 19cm |
1.7 | Bore depth | 56cm |
1.8 | 5 Gauss fringe field | 1m*1m*1m |
2 | Gradient System | |
2.1 | Gradient field strength (Single Axis) | 18mT/m |
2.2 | Gradient slew rate (Single Axis) | 54mT/m/ms |
2.3 | Rise time | 0.3ms |
2.4 | Gradient cooling | Air |
3 | RF System | |
3.1 | Spectrometer | Fully digital |
3.2 | RF system type | Digital |
3.3 | Number of RF channel | 2 |
3.4 | Transmitter amplifier peak power | 5kW |
3.5 | RF blanking | Yes |
3.6 | Dynamic range | ≥80dB |
3.7 | Noise factor | <0.3dB |
3.8 | Coil type | Phase array |
3.9 | Knee coil (L) | Available |
3.1 | Knee coil (S) | Available |
3.11 | Ankle coil | Available |
3.12 | Wrist coil | Available |
Remark:The coil configuration is subject to the final contract | ||
4 | Patient communication | |
4.1 | Max.patient weight | 135Kg |
4.2 | High accurate position assist | Yes |
4.3 | Localizer | Yes |
4.4 | Position accurate | ≤1mm |
4.5 | Table movement | Up-down |
In-out | ||
Rotation | ||
4.6 | Emergence stop | Yes |
4.7 | Communication system | Yes |
5 | Computer system | |
5.1 | Host computer | Dual core |
5.2 | System software | BASDA |
5.3 | OS | WINDOWS 7 |
5.4 | CPU clock rate | ≥2.8GHz |
5.5 | Main memory | ≥2GB |
5.6 | Color LCD monitor | 24" |
5.7 | Keyboard and mouse | Standard |
5.8 | Hard disk | ≥250GB |
5.9 | Media driver | CRW/DVD |
5.1 | DICOM 3.0 | Yes |
5.11 | Ethemet | Yes |
6 | Scanning parameter | |
6.1 | Max.FOV | 250mm |
6.2 | Min.FOV | 90mm |
6.3 | Min.2D Thickness | 2mm |
6.4 | Min.3D thickness | 0.2mm |
6.5 | Max.Image matrix | 256*256 |
7 | Scanning sequence &imaging technology | |
7.1 | Spin echo | Yes |
7.2 | Multi-slice multi-echo | Yes |
7.3 | Gradient echo | Yes |
7.4 | Turbo gradient echo technology | Yes |
7.5 | Fast spin echo | Yes |
7.6 | Fast double echo | Yes |
7.7 | Fast recover spin echo | Yes |
7.8 | Variable flip angle technology | Yes |
7.9 | Variable ETL technology | Yes |
7.1 | Inversion recovery | Yes |
7.11 | Inversion recovery fast spin echo | Yes |
7.12 | Short time inversion recovery | Yes |
7.13 | Fluid attenuated inversion recovery | Yes |
7.14 | Magnetization transfer technology | Yes |
7.15 | 3D position | Yes |
7.16 | Automatic coil tuning | Yes |
7.17 | Online image filtration | Yes |
7.18 | Online post procession | Yes |
7.19 | Optimal algorithm of active shimming | Yes |
7.2 | Scan sequence queuing | Yes |
7.21 | Multi-layer and multi-angle scanning technology | Yes |
7.22 | Optimize bandwidth acquisition technology | Yes |
7.23 | Flow compensation | Yes |
7.24 | Parallel acquisition technology | Yes |
7.25 | Scan parameter preset | Yes |
7.26 | Oversampling technology | Yes |
7.27 | Image fusion technology | Yes |
7.28 | Artifact suppression technology (K_Rotat) | Yes |
7.29 | Thin imaging technology | Yes |
7.3 | Post processing package | Yes |