SJD-U30 Fiber Optic LED Screen Oral Care Electric Surgical Dental Implant Motor System
Feature:
Unit Main Body
* One button operation, ease of use, super safe and convenient
* Freely programming for the needs of different users
* High definition LCD screen with no refection,satisfy for 360"glance
* Coolant volume at 100% reaches minimum 90m/min, starts simultaneously with hand piece to ensure sufficient water cooling for bur
* Automatic thread Cutter mode
* When this mode[P5] is activated, the speed in both forward and reverse modes is 20rpm and can no longer be changed
* When the foot pedal is pressed, the bur rotates inwards until the torque is reached
* When the set torque is reached,the bur automatically switches to reverse
* Disengaging and then re-engaging the foot pedal will switch the device back to forward operation
Implant Motor
* Slim size and artistic design
* Comfortable grip and ideal balance
* Torque range 5-70N.cm with 20:1 hand piece
Implant Motor Technical Specifications |
|
|
|
Motor without LED |
Motor with LED |
Maximum torque of motor |
5. 5N-cm |
5. 5N-cm |
Dimension of motor |
L 49xW22mm |
L 69xW23.9mm |
Net weight of motor |
110g |
139g |
Length of motor cable |
1.8m |
1.8m |
Autoclavable motor and cable |
134°C, last at lease 3 mins |
134°C, last at lease 3 mins |
The maximum noise of the motor without loading |
<40dB |
<40dB |
|
|
|
Motor with LED light at high color rendering index |
Natural daylight, adjustable brightness levels |
|
Implant Handpiece Technical Specifications |
|
Model |
RL20 |
Transmission ratio |
0.834027778 |
Maximum torque |
70Ncm |
Lighting mode |
Fiber optic |
Lighting color |
Natural daylight |
Chucking mode |
Push- button |
Cooling mode |
External spray |
Detachable |
Yes |
Indications, e.g. |
Implantation, Osteotomy |
Coupling standard |
ISO 3964,YY1012-2004 |
Implant Handpiece Technical Specifications |
|
Model |
R20 |
Transmission ratio |
0.834027778 |
Maximum torque |
70Ncm |
Lighting mode |
NO |
Lighting color |
No |
Chucking mode |
Push- button |
Cooling mode |
External spray |
Detachable |
No |
Indications, e.g. |
Implantation, Osteotomy |
Coupling standard |
ISO 3964,YY1012-2004 |
Foot Control
* Functions: Water Volume switch, program conversion, motor rotating direction control, stepless speed control
Foot Control Technical Specifications |
|
Waterproof level of foot control |
IPX6 |
Dimension of foot control |
200x210x85mm |
(L xWxH) |
|
Cable length of foot control |
2.8m |
Complete Unit Technical Specifications |
|
|
Model |
M1 |
M1-110V |
Maximum torque of bur |
70N. cm |
70N.cm |
PV |
220V+10%,50-60Hz |
110V+10%,50-60Hz |
Maximum output power |
70W |
70W |
Adjustable motor range rpm |
300-40000rpm |
300-40000rpm |
Coolant volume at 100% |
> 90ml/min |
> 90ml/min |
Transmission ratio P1,P2-P5 |
1:1 20: 1 |
1:1 20: 1 |
Program settings |
5 programs for individual adjustment of parameters |
|
Foot control |
IPX6 |
IPX6 |
Coolant pump |
Built-in |
Built-in |
Dimension of main unit(with steeve)(LxWxH) |
270x240x520mm |
270x240x520mm |
|
|
|
Dimension of packing(LxWxH) |
428x328x255mm |
428x328x255mm |
Net /Gross weight |
5.7/7.3kg |
5.7/7.3kg |
Colour of main unit body |
White |
White |
Material of tubing |
PVC Silicane tubing |
|
Total Length |
3 m |
|
Size of extrusion section |
External diameter: 6mm Internal diameter: 4mm |
|
Size of water spray section |
External diameter: 3 mm Internal diameter: 1 .4mm |
|
Medical equipment |
Sterile, disposable |
|
|
P1 |
P2 |
P3 |
P4 |
P4 |
P5 |
P5 |
|
|
|
|
Forward |
Reverse |
Forward |
Reverse |
Transmission ratio |
0.042361111 |
0.834027778 |
0.834027778 |
0.834027778 |
0.834027778 |
0.834027778 |
0.834027778 |
Default Speed rpm |
35000 |
1200 |
800 |
15 |
30 |
20 |
20 |
Adjustable rpm Range |
300-40000 |
15-2000 |
15-2000 |
- |
- |
- |
- |
Motor direction |
Forward |
Forward |
Forward |
Forward |
Reverse |
Forward |
Reverse |
Coolant pump |
On |
On |
On |
On |
Off |
On |
On |
Default torque(N-cm) with 20:1 HP |
1 |
1 |
1 |
20 |
60 |
20 |
20 |
Torque range(N.cm) |
- |
|
|
5-70 |
5-70 |
20-60 |
20-60 |
Recommended setting |
|
|
|
|
|
|
|
Positioning |
Initial hole |
Drill full hole |
Match implant thread |
Place implant |
Setting closure cap |
rpm |
1200-1500 |
1000-1200 |
800-1000 |
15 |
15 |
15 |
N.cm |
1 |
1 |
1 |
50 |
30 |
30 |
Coolant |
Third level |
Third level |
Third level |
Close |
Close |
Close |
volume level |
|
|
|
|
|
|
Hand piece ratio |
0.834027778 |
0.834027778 |
0.834027778 |
0.834027778 |
0.834027778 |
0.834027778 |