Feature:
* 15" color TFT display, high resolution 1024×768 dpi;
* Separated para board: ECG, NIBP, SpO2 board;
* Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
* Real time S-T segment analysis, and ARR analysis;
* SpO2 Pitch Tone Variation and Drug Dose Calculation;
* Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
* Standby mode for Energy saving and suspend monitoring;
* 7-lead ECG waveforms display in phase;
* Capture dynamic waveforms;
* Built-in rechargeable lithium battery, and battery volume checking.
* Efficient resistance to interference of defibrillator and HF knife;
* F-6 SpO2 workable for neonate;
* TCP/IP networking platform ena ble abundant future upgrade
* Complete and flexible mounting solution for transportation and in-patient monitoring
* Standard parameters: 5-lead ECG, SpO2(F-5), NIBP, RESP, TEMP, PR;
* Optional: Touch Screen, Thermal Recorder, 3/12- lead ECG, 2/4-1BP, EtCO2, SpO2(F-6) , Multi-gas, Cardiac Output
Parameters |
|
ECG |
|
Lead mode |
3/5-lead (R, L, F, N, C) |
Lead selection |
l, ll, lll, avR, avL, avF, V |
Waveform |
3 and 7 channel selectable |
Gain selection |
0.5mm/mv, 1mm/mv, 2mm/mv |
Sweep speed |
12.5mm/s, 25mm/s, 50mm/s |
Heart rate range |
Adult: 15~300bpm; Neonate/pediatric: 15~350bpm Accuracy: +1bpm or +1%, whichever is greater; Resolution: 1bpm |
Filter |
Surgery mode: 1~20Hz, Monitor model: 0.5~40Hz, Diagnostic mode: 0.05~130Hz |
|
Scaling signal: 1mv, +3% |
Protection |
withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation |
Alarm range |
15~350bpm |
S-T segment detecton |
Measurement range: 2.0mV~+2.0mV; Alarm Range: -2.0mV~ +2.0mV Accuracy: -0.8mV ~+0.8Mv; Error: +0.02Mv |
Arrhythmia analysis |
YES |
SPO2 |
|
Measurement range |
0~100%; Resolution: 1%, Accuracy: +2%(70-100%); 0-69°/o unspecified |
Alarm range |
0~100% |
Pluse Rate |
Range: 20~300bpm, Resolution: 1bpm; Error: +1bpm or +2%,whichever is greater |
NIBP |
|
Method |
Digital Automatic oscillometric |
Operation mode |
Manual/Automatic/continuous |
Auto measurement time |
Adjustable (1~480 min) |
Measurement Unit |
mmHg/Kpa selectable |
Measurement types |
Systolic, Diastolic, Mean |
Measurement tange |
Range of Systolic pressure: Adult: 40~270mmHg, Pediatric: 40~220mmHg, Neonate: 40~135mmHg Range of mean pressure: Adult: 20~235mmHg, Pediatric: 20~165mmHg, Neonate: 20~110mmHg Range of diastolic pressure: Adult: 10~215mmHg, Pediatric: 10~150mmHg, Neonate: 10~100mmHg |
Over-pressure protection |
Double safety protection |
Resolution |
1 mmHg |
Alarm |
Systolic, Diastolic, Mean |
RESPIRATION |
|
Method |
Thoracic impedance |
Measurement range |
Adult: 7~120rpm, Neonate/Pediatric: 7~150rpm Resolution: 1rpm, Accuracy: +2rpm |
Apnea alarm |
YES, 10~40s |
TEMP |
|
Compatible probe |
YSI or CYF |
Measurement range |
5~50°C, Resolution: 0.1°C, Accuracy: +0.1°C |
Refreshing time |
about 1 |
Average measuring time |
<10s |
Optional Parameters |
|
RECORDER |
|
Recorder |
Build-in, thermal array |
Record mode |
Manual, on alarm, time-defined |
Plethysmogram caveform |
2 channels |
Recording width |
50 mm |
Printing speed |
50mm/s |
Recording type
|
Frozen waveform record, NIBP recall record, Trend table record Alarm record, Fixed -time record |
IBP (invasive blood pressure) |
|
IBP Waveform |
2-Channel, Max 8 channels |
Measurement Range |
50~+350mmHg |
Resolution |
1mmHg, Unit: mmHg, kPa |
Accuracy: |
Dynamic: ±4mmHg or 4%, whichever is greater |
Sensitivity of transducer |
5 uV/V/mmHg, ±2% |
Impedance of transducer |
300~3000 |
Ohm Transducer sites |
Arterial Pressure(ART) Pulmonary Artery Pressure(PA) Left Atrium Pressure(LAP) Right Atrium Pressure(RAP) Central Venous Pressure(CVP) Intracranial PRESSURE(ICP) P1/P2 |
Selection of measurement range |
ART: 0~+350mmHg PA: -10~+120mmHg CVP/RAP/LAP/ICP: -10 ~+ 40mmHg P1/P2: -50~+360mmHg |
![]() |
![]() |
OPM9000 8 inch Patient Monitor | OPM8H 8 inch Patient Monitor |
![]() |
![]() |
OPM12IE 12.1 inch Multi-parameter Monitor | OPM15IE 15 inch Multi-parameter Monitor |
![]() |
![]() |
OPM8000D 15 inch Multi-parameter Monitor | OPM8000AU 8 inch Patient Monitor |